Ladder Logic Table of Contents

KronoTech

PLC

Ladder Logic

Table of Content

Basic

XIC

XIO

OTE

ONS

OTL

OTU

Basic Motors

Counters

Timer

Arithmetic

Comparison

Functions

Trig Functions

RSLogix 5000

Structured Text

HMI

Instruments

Ladder Logic in a Nutshell is an easy guide to Ladder Logic Programming. This book has been designed to thoroughly examine all the basic instructions in Ladder Logic in an easy step by step methode.

To order your copy click here

Chapter 1 : PROGRAMMABLE LOGIC CONTROLLERS

  • PROGRAMMABLE LOGIC CONTROLLER (PLC)
  • INTRODUCTION
  • ADVANTAGES AND DISADVANTAGES
  • VISUAL OBSERVATION
  • LADDER LOGIC
  • I/O Modules INPUT / OUTPUT
  • RACKS AND CHASIS
  • INPUT AND OUTPUT MODULES
  • PROGRAMMING LANGUAGES
  • CONNECTIONS

Chapter 2: BASIC INSTRUCTIONS

  • INTRODUCTION
  • DEFINITION
  • XIC - Examine if Closed
  • XIO - Examine if Open
  • OTE - Output Energize
  • OTL - Output Latch
  • OTU - Output Unlatch
  • OSR - One-Shot Rising
  • TON - Time On-Delay
  • TOF - Timer Off-Delay
  • RTO - Retentive Timer
  • CTU - Count UP
  • CTD - Count Down
  • RES - Reset

Chapter 3 : MATH INSTRUCTIONS

  • INTRODUCTION
  • STATUS FILE
  • DEFINITION
  • PRACTICE
  • ADD - Adding
  • SUB - Subtract
  • MUL - Multiply
  • DIV - Divide
  • DDV - Double Division
  • CLR - Clear
  • SQR - Square Root
  • SCP - Scale with Parameter
  • SCL - Scale Data
  • ABS - Absolute Value
  • CPT - Compute
  • SWP - Swap
  • XPY - X to the Power of Y
  • ASN - Arc Sine
  • ACS - Arc Cosine
  • ATN - Arc Tangent
  • COS - Cosine
  • LN - Natural Log
  • LOG - Log to the Base 10
  • SIN - Sine
  • TAN - Tangent

Chapter 4: COMPARISON

  • INTRODUCTION
  • DEFINITION
  • EQU - Equal
  • NEQ - Not Equal
  • LES - Less Than
  • LEQ - Less Than or Equal
  • GRT - Greater Than
  • GEQ - Greater or Equal
  • MEQ - Masked Comparison for Equal
  • LIM - Limit Test

Chapter 5: FLOW CONTROL

  • INTRODUCTION
  • DEFINITION
  • JMP / LBL - Jump / Label
  • JSR / SBR / RET - Jump to subroutine / Subroutine / Return
  • MCR - Master Control Reset
  • TND - Temporary End
  • SUS - Suspend
  • IIM - Immediate Input with Mask
  • IOM - Immediate Output with Mask
  • REF - Refresh

Chapter 6: DATA HANDLING INSTRUCTIONS

  • INTRODUCTION
  • DEFINITION
  • TOD - Convert BCD
  • FRD - Convert From BCD
  • DEG - Convert from Radians to Degrees
  • RAD - Convert from Degrees to Radians
  • DCD - Decode 4 to 1 of 16
  • ENC - Encode 1 of 16 to 4
  • COP / FLL - Copy File / Fill File
  • MOV - Move
  • MVM - Masked with Move
  • AND - Boolean AND
  • OR - Boolean OR
  • XOR - Boolean XOR
  • NOT - Boolean NOT

Chapter 7: STACKERS AND ARRAYS

  • DEFINITION
  • BSL / BSR - Bit Shift Left / Bit Shift Right
  • FFL / FFU - FIFO Load / FIFO unload
  • LFL / LFU - LIFO Load / LIFO Unload

Chapter 8: STEP BY STEP

  • Flash Code
  • Toggle Push Button
  • Motor Logic
  • Jump Simulation
  • JSR Simulation
  • BSR Bit Shift Right

Quick Links

PLC Languages

Ladder Logic
Function Block
Structure Text
SFC
Mnemonic

Ladder Logic

Basic
Counters
Timer
Arithmetic
Comparison
Functions
Trig Functions

Instruments

Switches

HMI

Alarms
Recipe
Trends

Other

Bottle Application